What was found
INSPECTION FOUND MAIN CABIN FLOORBEAM UPPER FLANGE CORRODED AT STA 328, WL 208. A NEW FLOORBEAM SECTION WAS INSTALLED IAW SRM 53-10-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND MAIN CABIN FLOORBEAM UPPER FLANGE CORRODED AT STA 328, WL 208. A NEW FLOORBEAM SECTION WAS INSTALLED IAW SRM 53-10-51.