What was found
INSPECTION FOUND FLOORBEAM CORRODED AT BS 740 FROM RBL 9 TO LBL 4. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, FIGURE 203.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM CORRODED AT BS 740 FROM RBL 9 TO LBL 4. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, FIGURE 203.