What was found
INSPECTION FOUND A 1 INCH CRACK IN EXTERNAL SKIN BETWEEN STA 947.5 AND 967, S10L TO S11L (L-2 DOOR UPPER HINGE CUTOUT FORWARD CORNER RADIUS JUST BELOW THE RAIN GUTTER). A REPAIR WAS INSTALLED IAW SRM 53-60-01, FIGURE 205. A DIP WAS ISSUED TO REINSPECT THE AREA WHEN AIRFRAME HAS ACCUMULATED A TOTAL OF 60,000 CYCLES. THEN ACCOMPLISH REPETITIVE INSPECTIONS EVERY 4,000 CYCLES THEREAFTER AND WITHIN EVERY 15,000 CYCLES AFTER INITIAL, ACCOMPLISH MFEC INSPECTION OF BEARSTRAP INTERNALLY.