What was found
THE OVERWING DOOR EMERGENCY EXIT LIGHTS WERE FOUND INOPERATIVE (LEFT OUTSIDE FORWARD AND RIGHT OUTSIDE FORWARD AND AFT). THE BATTERY CHARGER WAS REMOVED AND REPLACED IAW MM 33-51-00. OPERATION CHECKED GOOD ON AFT RIGHT LIGHT. RELAMPED FORWARD LEFT AND FORWARD RIGHT BULBS AND OPERATION CHECKED GOOD.