What was found
INSPECTION FOUND THE AFT CARGO COMPARTMENT DOOR CUTOUT FORWARD FRAME CORRODED ON I/B SIDE AT STA 794, L26R TO L27R. THE CORRODED AREA WAS CUT OUT AND DOUBLER AND FILLER WERE INSTALLED IAW SRM 51-70-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND THE AFT CARGO COMPARTMENT DOOR CUTOUT FORWARD FRAME CORRODED ON I/B SIDE AT STA 794, L26R TO L27R. THE CORRODED AREA WAS CUT OUT AND DOUBLER AND FILLER WERE INSTALLED IAW SRM 51-70-11.