As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION FOUND THE EMERGENCY LIGHT INOPERATIVE AT OVERWING ESACPE HATCH, ROWS 11-14. TROUBLESHOOTING ISW WDM 33-51-13 FOUND AN OPEN FUSE ON BATTERY PACK M1694. THE FUSE WAS REMOVED AND REPLACED IAW STANDARD WIRING PRACTICES MANUAL 20-00-00. OPS CHECK WAS GOOD.