What was found
INSPECTION FOUND FLOOR STRINGERS AT CROSS STRAP IN AFT BAG BIN CORRODED AT STA 1467, LBL 26. THE CORROSION WAS REMOVED AND ONE AREA WAS OUT OF LIMITS. A REPAIR WAS INSTALLED IAW SRM 51-70-11, FIGURE 1. THE OTHER AREAS WITHIN LIMITS WERE TREATED AND PRIMED IAW SRM 53-00-53.