What was found
INSPECTION FOUND FORWARD FLOOR STRUCTURE T-CAP (FLOORBEAM UPPER CHORD) CORRODED AT STA 312, LBL 29 APPROXIMATELY 24 INCHES O/B OF L-1 DOOR THRESHOLD. THE FLOORBEAM UPPER CHORD WAS REPAIRED IAW ECRA 5321-01323.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FORWARD FLOOR STRUCTURE T-CAP (FLOORBEAM UPPER CHORD) CORRODED AT STA 312, LBL 29 APPROXIMATELY 24 INCHES O/B OF L-1 DOOR THRESHOLD. THE FLOORBEAM UPPER CHORD WAS REPAIRED IAW ECRA 5321-01323.