What was found
INSPECTION FOUND A .75 INCH CRACK IN STRINGER SPLICE CHANNEL AT STA 360, S14L AFT OF L-1 DOOR. A REPAIR WAS INSTALLED IAW ECRA 5310-04535.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .75 INCH CRACK IN STRINGER SPLICE CHANNEL AT STA 360, S14L AFT OF L-1 DOOR. A REPAIR WAS INSTALLED IAW ECRA 5310-04535.