What was found
INSPECTION FOUND FLOOR FRAME CORRODED AROUND FASTENER HOLES AT STA 986.5, RBL 23 TO RBL 43. THE CORRODED AREA WAS CUT OUT AT THREE EACH LOCATIONS AND ANGLES, FILLERS, AND SHEAR CLIPS (FRAME TO BEAM) WERE INSTALLED IAW ECRA 5321-01383.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR FRAME CORRODED AROUND FASTENER HOLES AT STA 986.5, RBL 23 TO RBL 43. THE CORRODED AREA WAS CUT OUT AT THREE EACH LOCATIONS AND ANGLES, FILLERS, AND SHEAR CLIPS (FRAME TO BEAM) WERE INSTALLED IAW ECRA 5321-01383.