What was found
INSPECTION FOUND FLOORBEAM CORRODED AT STA 1016, S19L, LBL 10-12. A REPAIR STRAP AND SHIM WERE INSTALLED IAW SRM 53-00-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM CORRODED AT STA 1016, S19L, LBL 10-12. A REPAIR STRAP AND SHIM WERE INSTALLED IAW SRM 53-00-51.