What was found
INSPECTION FOUND FLOORBEAM CORRODED ON TOP AND BOTTOM AT STA 986.5, RBL 43. A REPAIR STRAP WAS INSTALLED IAW SRM 53-00-51, FIGURE 201, REPAIR 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM CORRODED ON TOP AND BOTTOM AT STA 986.5, RBL 43. A REPAIR STRAP WAS INSTALLED IAW SRM 53-00-51, FIGURE 201, REPAIR 3.