What was found
INSPECTION FOUND A 1 INCH CRACK IN FORWARD CARGO DOOR CUTOUT FORWARD FRAME AT LOWER STOP PAD, STA 400, S17R TO S28R. A NEW FRAME WAS INSTALLED IAW SRM 51-10-02 AND 51-40-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 1 INCH CRACK IN FORWARD CARGO DOOR CUTOUT FORWARD FRAME AT LOWER STOP PAD, STA 400, S17R TO S28R. A NEW FRAME WAS INSTALLED IAW SRM 51-10-02 AND 51-40-00.