What was found
INSPECTION FOUND SURFACE CORROSION AROUND SCREW HOLES ON FLOORBEAM AT STA 1016 FROM LBL 30 TO LBL 34, S19L-S21L. THE CORROSION WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM 53-00-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND SURFACE CORROSION AROUND SCREW HOLES ON FLOORBEAM AT STA 1016 FROM LBL 30 TO LBL 34, S19L-S21L. THE CORROSION WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM 53-00-51.