What was found
INSPECTION FOUND A .75 INCH CRACK IN STUB FRAME FOR L-2 DOOR UPPER HINGE AREA, STA 947.5, S11L. THE FRAME WAS REPAIRED IAW ECRA 5311-01335.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .75 INCH CRACK IN STUB FRAME FOR L-2 DOOR UPPER HINGE AREA, STA 947.5, S11L. THE FRAME WAS REPAIRED IAW ECRA 5311-01335.