What was found
INSPECTION FOUND A .5 INCH CRACK IN STRINGER 16L JUST AFT OF STA 500C FORWARD OF WING SCANNING LIGHT HOUSING. THE STRINGER WAS REPAIRED IAW SRM 53-00-03, PAGE 201, FIGURE 201, REPAIR 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK IN STRINGER 16L JUST AFT OF STA 500C FORWARD OF WING SCANNING LIGHT HOUSING. THE STRINGER WAS REPAIRED IAW SRM 53-00-03, PAGE 201, FIGURE 201, REPAIR 1.