What was found
INSPECTION FOUND STRINGER 16L CHANNEL CRACKED AT FASTENER HOLE COMMON TO WEB AND CLIP AT STA 360. MULTIPLE CRACKS WERE FOUND IN THE SAME LOCATION, REPAIRED IAW ECRA 5311-01378.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND STRINGER 16L CHANNEL CRACKED AT FASTENER HOLE COMMON TO WEB AND CLIP AT STA 360. MULTIPLE CRACKS WERE FOUND IN THE SAME LOCATION, REPAIRED IAW ECRA 5311-01378.