What was found
CABIN FWD ENTRY FLOOR SUPPORT STA 294.5 AND RBL 31.5 PREVIOUS REPAIR STRAP HAS CORROSION UNDER, AROUND NUT PLATE HOLE. INSTALLED SECT "T" CHORD AND REINSTALLED STRAP PER SRM 53-10-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FWD ENTRY FLOOR SUPPORT STA 294.5 AND RBL 31.5 PREVIOUS REPAIR STRAP HAS CORROSION UNDER, AROUND NUT PLATE HOLE. INSTALLED SECT "T" CHORD AND REINSTALLED STRAP PER SRM 53-10-51.