What was found
CABIN - STA 303 LBL 15 TO LBL 45 FLOORBEAM FOUND CORROSION. CABIN FLOORBEAM CORROSION AREA REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AT STA 303 LBL 4 IN TO LBL 63 IN.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN - STA 303 LBL 15 TO LBL 45 FLOORBEAM FOUND CORROSION. CABIN FLOORBEAM CORROSION AREA REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AT STA 303 LBL 4 IN TO LBL 63 IN.