What was found
CABIN - STA 303 LBL 17 TO 35 FLOOR SUPPORT FOUND CORRODED. CABIN STA 303 LBL 17 TO LBL 35 FLOORBEAM REPAIRED PER SRM 53-00-51 FIG 201 REPAIR 1, HFEC FOUND NO CRACK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN - STA 303 LBL 17 TO 35 FLOOR SUPPORT FOUND CORRODED. CABIN STA 303 LBL 17 TO LBL 35 FLOORBEAM REPAIRED PER SRM 53-00-51 FIG 201 REPAIR 1, HFEC FOUND NO CRACK.