What was found
GENERATED DIP DUE TO HEAVY CORROSION AT STATION 967, STR 27LT TO STR 27RT, PERFORM A PERMANET REPAIR PER EC/RA 5331-01244 WITHIN 6,000 FLIGHT CYCLES OR 24 MONTHS, WHICHEVER OCCURS FIRST. DURING OPEN-UP FOUND MORE CORROSION, REMOVED EXISTING REPAIRS AND REPAIRED PER EC/RA 5330-03827.