What was found
RIGHT FRAME IS CRACKED AT FASTENER FOR AIR GRILL SUPPORT RAIL MOUNT LOCATED AT STATION 400 BETWEEN STRINGERS 8 AND 9. REMOVED DAMAGED AREA, AND INSTALLED REPAIR DOUBLERS A AND B PER EA 5310-04498 OPS-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT FRAME IS CRACKED AT FASTENER FOR AIR GRILL SUPPORT RAIL MOUNT LOCATED AT STATION 400 BETWEEN STRINGERS 8 AND 9. REMOVED DAMAGED AREA, AND INSTALLED REPAIR DOUBLERS A AND B PER EA 5310-04498 OPS-2.