What was found
E AND E COMPARTMENT M/D FLOORBEAM STATION 246 LBL 40 VERTICAL STIFFENER FOUND CRACKED. MAIN DECK FLOOR BEAM STATION 246 LBL 40 VERTICAL STIFFENER REPAIRED PER ECRA 5310-04854 PART 1. HFEC NIL CRACKS FOUND. REF L/P 7984436 53-DIP, 90691, DIP ISSUED TO PERFORM REPEAT INSPECTION PER ECRA5310-04854. LOG CLOSED, DIP REF TO L/P 7984436.