What was found
BODY STATION 325 FLOOR SUPPORT FOUND CORRODED BETWEEN LBL 26 -59. BODY STATION 325 FLOORBEAM LBL 13 - LBL 62 REPAIRED PER SRM 53-00-51 REPAIR 1, FIG 201. HFEC NO CRACK FOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BODY STATION 325 FLOOR SUPPORT FOUND CORRODED BETWEEN LBL 26 -59. BODY STATION 325 FLOORBEAM LBL 13 - LBL 62 REPAIRED PER SRM 53-00-51 REPAIR 1, FIG 201. HFEC NO CRACK FOUND.