What was found
CABIN BODY STATION 325 FLOOR SUPPORT FOUND CORRODED BETWEEN LBL 27-56. BODY STATION 325 FLOORBEAM SUPPORT BETWEEN LBL 6 TO LBL 64 REPAIRED PER SRM 53-00-51 REPAIR 1, FIG 201. HFEC NO CRACK FOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN BODY STATION 325 FLOOR SUPPORT FOUND CORRODED BETWEEN LBL 27-56. BODY STATION 325 FLOORBEAM SUPPORT BETWEEN LBL 6 TO LBL 64 REPAIRED PER SRM 53-00-51 REPAIR 1, FIG 201. HFEC NO CRACK FOUND.