What was found
FLOOR SUPPORT FOUND CORRODED AT BODY STATION 325 BETWEEN LBL 26-59 AFTER FLOOR PANEL REMOVED. CABIN BODY STATION 325 BETWEEN LBL 26 - LBL 60 FLOOR SUPPORT BEAM REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AND HFEC NO CRACK FOUND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT FOUND CORRODED AT BODY STATION 325 BETWEEN LBL 26-59 AFTER FLOOR PANEL REMOVED. CABIN BODY STATION 325 BETWEEN LBL 26 - LBL 60 FLOOR SUPPORT BEAM REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AND HFEC NO CRACK FOUND.