What was found
FLOORBEAM SUPPORT HAS CORROSION BETWEEN STA 700 -720 AND RBL-24. FABRICATED AND INSTALLED INTERCOSTAL AND SHIMS PER ECRA5310-04900. FABRICATED AND INSTALLED REPAIR SECTION TO UPPER T-CHORD PER SRM 53-00-51 FIG 201 REPAIR 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM SUPPORT HAS CORROSION BETWEEN STA 700 -720 AND RBL-24. FABRICATED AND INSTALLED INTERCOSTAL AND SHIMS PER ECRA5310-04900. FABRICATED AND INSTALLED REPAIR SECTION TO UPPER T-CHORD PER SRM 53-00-51 FIG 201 REPAIR 3.