As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME AT STA 1640 BETWEEN STR 5RT & AMP; 6RT CHAFED INTO ON I/B FLANGE. REPAIRED DAMAGED FRAME FLANGE REF ECRA 5310-04921. INSTALLATION OF REPAIR ANGLE STEPS 1-12 AND ISSUED DIP FOR PERMANENT REPAIR REF STEP 13. ACCOMPLISH PERM REPAIR WITHIN 12 MONTHS FROM 3/24/2009. PLANNING TO CONTACT ENGR AFTER 10 MONTHS BUT BEFORE 11 MONTHS FOR A PER REPAIR.