What was found
OIL CANNING AT AFT PRESSURE BULKHEAD OUTER PERIMETER STATION 1016 BETWEEN S-16R AND S-18R APPROXIMATELY 9 INCHES LONG, 6 INCHES WIDE AND .1875 INCH DEEP. INSTALLED REPAIR IAW SRM 53-80-08, REPAIR 2 AND ECRA 5310-04639 REV A AND ECRA 5311-01455. INITIATED DIP TO ACCOMPLISH A HFEC INSPECTION OF APBH REPAIR PER ECRA 5311-01455 PART 2, TABLE1 W/I 36,000FLT CYCLES FROM WHEN REPAIR INSTALLED. NOT TO EXCEED 24,000 F/CYC.