What was found
AFT PRESSURE BULKHEAD FWD END FITTING CORRODED AT STR 22R. REMOVED AND REPLACED DAMAGED FITTING REF SRM 51-40-02, BAC DWG 147A1116 AND SRM 51-40-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PRESSURE BULKHEAD FWD END FITTING CORRODED AT STR 22R. REMOVED AND REPLACED DAMAGED FITTING REF SRM 51-40-02, BAC DWG 147A1116 AND SRM 51-40-04.