What was found
WATER COMING OUT OF AFT CARGO PIT BELLY DRAINS. REMOVED AND REPLACED WATER LINE, FOUND BRACKETS (212N3042Y3) SUPPORTING APU BLEED LINE BROKEN CAUSING LINE TO BREAK WATER LINE (AS4796-12-0282).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WATER COMING OUT OF AFT CARGO PIT BELLY DRAINS. REMOVED AND REPLACED WATER LINE, FOUND BRACKETS (212N3042Y3) SUPPORTING APU BLEED LINE BROKEN CAUSING LINE TO BREAK WATER LINE (AS4796-12-0282).