What was found
B767-53-3-0172 STA 325 LBL 55 TO RBL 55 FLOORBEAM UPPER CHORD FOUND SEVERAL CORRODED. BS 325 FLOORBEAM UPPER CHORD CORROSION REMOVED AS PER SRM 51-10-02, BLEND OUT D0.035" (ORG THK 0.090") W1"L2.5" OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMITS & FLOORBEAM UPPER CHORD CORRODED AREA REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AT BS 325 LBL 63 TO RBL 55 & FORM 44.0008 ATTACHED ITEM 1 TO 10 ACCOMPLISHED.