What was found
B767-53-3-0172 STA 303 LBL 11 TO 55 FLOORBEAM UPPER CHORD FOUND SEVERAL CORRODED. BS 303 FLOORBEAM UPPER CHORD CORROSION REMOVED AS PER SRM 51-10-02, BLEND OUT AREA DEPTH 0.060" (ORG THK 0.100") WIDTH 1 INCH, LENGTH 3 INCHES OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMIT AND FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AT BS 303 LBL 7 TO LBL 63 & FORM 44.0008 ATTACHED ITEM 1 TO 10 ACCOMPLISHED.