As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TB5060H, TERMINAL 3, IS BURNT AND ATTACHING WIRES W0040-0047- 10 AND W2132-0003-08 ARE ARCED TOGETHER AT THE TERMINAL LUGS. NOTE: THIS IS AN EXISTING CONDITION FOUND DURING ACCOMPLISHMENT OF EA 2420-01454. REPLACED TERMINAL STRIP TB5060H IAW IPC24-51-11, RE-TERMINATED BURNT LUGS IAW SWPM 20-30-11. POWER-ON OPS CHECK IS GOOD AS PERFORMED ON EA 2420-01454. TERMINAL STRIP LOCATED AT STA 280 & RBL-60.