What was found
SUPPORT TASK - LT HORIZONTAL STAB BOTTOM SKIN PANEL HAS A CRACK. LOCATION IMMEDIATELY I/B OF RIB AT STA 129.5 AND 26 INCHES AFT OF L/E. CRACK LENGTH APPROX 1 INCH LONG. REPAIRED PER ECRA5510-02089. PARTIAL WORKED ACCOMPLISHED IN THE BACK OF NR AND FORM 44.0008 ATTACHED. DIP TO ACCOMPLISHED A PERMANENT REPAIR WITHIN 12 MONTHS FROM 2/26/2010. PLANNING TO CONTACT ENGINEERING AFTER 10 MONTHS BUT BEFORE 11 MONTHS FOR A PERMANENT REPAIR. QC - ACCOMPLISH A PERMANENT REPAIR WITHIN THE 12 MONTHS FROM 02/26/2010. PLANNING TO CONTACT ENGINEERING AFTER 10 MONTHS BUT BEFORE 11 MONTHS FOR A PERMANENT REPAIR BEFORE 02/26/2011. PER ECRA 5510-02089. DIP CTL# 03776 1) INIT: AFTER 10 BUT BEFORE 11 MONTHS & 2) T/A: 12 MONTHS FROM 26 FEB 2010 (DUE 26 FEB 2011).