What was found
EXTERNAL SKIN STA 1560 S28L-S29L FOUND PREVIOUS DOUBLER REPAIR WITHOUT RECORD. FUSE EXT SKIN DOUBLER REPAIR REPLACED AND INSTALLED AS PER SRM 53-00-01 REPAIR 3 FIG 201. FORM 44.0008 ITEMS 1 TO 17 ACCOMPLISHED. DIP RAISED FOR REPEAT INSP AFTER 37.5K CYCLES, EVERY 3K OR 6K AS APPLICABLE REF SRM 53-00-01 REPAIR 3 FIG 201 TABLE V 53-DIP C/N 03714. INSTALLED FUSELAGE SKIN REPAIR, STA 1560, STR 28LT TO STR 29LT. INITIAL THRESHOLD IS 25,000 FLT CYC PER SRM 53-00-01, REPAIR 3 FIG 201 PER TABLE V, INSPECT AND INTERVALS OF 3000 FLT CYC THEREAFTER LFEC PER CHART V OF SRM REPAIR AT 37,500 TOTAL FLT CYC`S, THEREAFTER EVERY 3,000 FLT 53-00-01 REPAIR 3 OF PG 207. NOTE DOUBLER THICKNESS REPORTED TO CYC`S FOR HFEC OR 6,000 FLT CYC`S FOR LFEC INSPECTIONS. CAT B BE .064 THICK, CATEGORY B REPAIR. REPAIR. 1) INIT: W/I 25000 F/C. INIT WILL AUTO-ITO TO 2) RIR: EVERY 3000 F/C THEREAFTER (M&E 53-9953-8-0340).