What was found
RAMP REPORTED DENT JUST FWD OF L-2 DOOR ON FUSELAGE. DENT IS AT STA 613.5 BETWEEN ST 15L AND 16L CHANGED ATA 5300 TO 5330. DENT MEASURES 3"X 3.375" AND 0.105"D A/Y=28.57 DENT W/I SRM 53 -00-01 A/D1 LIMITS. MUST INITIATE DIP TO EXAMINE DNET EVERY 300 FLT CYCLES AND PERMANENT REPAIR AT OR BEFORE NEXT C-CK NOT TO EXCEED 24 MOS. RE-INSPECTED DENT WITHIN LIMITS PER SRM 53-00-01 A/D1 LIMITS, NO OTHER DEFECTS NOTED. DIP REMAINS OK FOR SERVICE INSPECTED AREA, NO PROGRESSION NOTED, DIP REMAINS. RE-INSPECTED DENT, NO PROGRESSION NOTED. DIP REMAINS. INSPECTED DENT ON FUSELAGE FWD OF L2 DOOR , NO PROGRESSION NOTED , NO CRACKS NOTED. DIP REMAINS. INSPECTED DENT FORWARD OF L-2 DOOR PER SRM 53-00-01. NO OTHER DAMAGE OR PROGRESSION NOTED. DIP REMAINS. OK TO CONTINUE REPAIRED DENT WITH FLUSH SKIN REPAIR REF SRM 757-300 CHAP 53-00-01 REPAIR 7 PG 203. ALL PARTIAL WORK NOTED ON ATTACHED FORM 44.0008 SHT 1 AND SHT 2, OK TO CONTINUE. DIP 91231 CLOSED. RE-INSPECT EVERY 300 FLT CYC & PERM REPAIR WITHIN NEXT C-CK (6000 FLT HRS/3000 FLT CYC/547 DAYS) NOT TO EXCEED 24 MONTHS. 1) RIR: EVERY 300 F/C & 2) T/A: W/I 6000 F/H OR 3000 F/C OR 547 DAYS.