What was found
SUPPORT TASK. CABIN FLOOR STRUCTURE, O/B CREASE BEAM CHORD AT STA 1040 RBL 65 HAS LIGHT SURFACE CORROSION. REMOVED CORROSION, FABRICATED AND INSTALLED REPAIR ANGLES AND SHIMS REF ECRA 5310-05170. CREATED DIP WITH THIS LOG PAGE ITEM 53-DIP CONTROL NUMBER 05015 PER PART 4 OF SAME ECRA. ACCOMPLISH PERM REPAIR WITHIN 24 MONTHS FROM 5/10/2010. PLANNING TO CONTACT ENGR AFTER 22 MONTHS BUT BEFORE 23 MONTHS FOR A PERM REPAIR.