LEFT HYD QTY LOSS AFTER TAKEOFF, FOLLOWED BY LOSS OF HYD PRESSURE FOUND RT MLG DOWNLOCK ACTUATOR HYD SUPPLY LINE BROKEN. R&R IAW IPC 32-32-51-16. OPS AND LEAK CHECKS GOOD. AIR RETURN AIRCRAFT WAS 10 MIN OUT.