What was found
O2 MASK AUTO ACTUATION FUNCTION TEST FAILED FOUND RELAY R322 BAD R&R RELAY R322 AUTO ACTUATION FUNCTION, TEST PASSED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
O2 MASK AUTO ACTUATION FUNCTION TEST FAILED FOUND RELAY R322 BAD R&R RELAY R322 AUTO ACTUATION FUNCTION, TEST PASSED.