What was found
SUPPORT TASK FWD ENTRY DOOR LOWER HINGE CUTOUT HAS CRACKED INDICATION AT FASTENER HOLE JUST 3 INCHES BELOW STRINGER 13L AND FRAME STA 303.90 AREA REF B737 NDT MANUAL PART 6 CHAPTER 51-00- 00 FIG 16 OVERSIZED, HFEC INSPECTED, & ENDOSCOPE HOLE; CONFIRMED TO BE DRILLED THRU LWR SKIN; FABRICATED, DRILLED, & INSTALLED TRIPLER, DOUBLER, & FILLER; TREATED & PRIMED ALL REPAIR PARTS REF ECRA 5 330-04063.