What was found
CRUISE FLT FL300 MASTER WARNING WHEEL WELL FIRE LIGHT AND BELL W/ 3 GEAR UNSAFE LIGHTS. RAN QRH LIGHTS EXTINGUISHED AFTER 3-4 MIN. LANDING NORMAL 3 GREEN ONCE GEAR EXTENDED AND LOCKED. INSPECTED CONNECTORS D4574P AND D4834P FOR CONTAMINATION /MOISTURE, NO DEFECTS FOUND. REF WD 26-12-11. WHEEL WELL OVERHEAT DETECTION SYSTEM OPS CHECKS GOOD PER AMM 26-17-00. LANDING GEAR POSITION INDICATING AND WARNING SYSTEM OPS CHECKS GOOD PER AMM 32-61-00. (CYCLED GEAR 10 TIMES-NO FAULTS) "FOR SDR REPORTING".