What was found
LT LOWER EXTERNAL FUSELAGE, 2 DENTS SIDE BY SIDE AT STA 430 AT 22L COMPLIED WITH ECRA 5330-04110 STEPS A, B AND C 1 THROUGH 8. INITIATED DIP TO ACCOMPLISH A PERMANENT REPAIR PER PART 3 WITHIN 24 MONTHS. PER ECRA 5330-04110 ORIG, PART 1, STEP C, 8, ACCOMPLISH A PERMANENT REPAIR PER PART 3 WITHIN 24 CALENDAR MONTHS. NOTE TO PLANNING. CONTACT ENGINEERING AFTER 22 CALENDAR MONTHS BUT BEFORE 23 CALENDAR MONTHS FOR PERMANENT REPAIR INSTRUCTIONS.