What was found
MAIN CABIN FLOORBEAM 1641 BL 0 HAS CORROSION. REMOVED CORROSION FROM FLOORBEAM STA 1641. FOUND TO BE OUT OF LIMITS. REMOVED DAMAGE SECTION AND SPLICED IN NEW SECTION. REF S SRM 53-00-51 REPAIR 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOORBEAM 1641 BL 0 HAS CORROSION. REMOVED CORROSION FROM FLOORBEAM STA 1641. FOUND TO BE OUT OF LIMITS. REMOVED DAMAGE SECTION AND SPLICED IN NEW SECTION. REF S SRM 53-00-51 REPAIR 3.