What was found
BS 303.9 FRAME CRACKED AT STR 16L FORWARD SIDE AROUND OVAL HOLE. INSTALLED REPAIR PER ECRA 5311-01515. GENERATED DIP TO REINSPECT BEFORE THE ACCUMULATION OF 66000 TOTAL A/C FLY CYCLES PER PART 2 OF ECRA 5311-01515 REF DIP 08205 FRAME CRACKED STA 303.9 PER ECRA 5311-01515 COMPLETED REPAIR. INSPECT REPAIR AT 66,000 TOTAL FLT CYC`S. PLANNING TO CONTACT ESC AFTER 60,000 TOTAL FLT CYC`S NOT TO EXCEED 61,000 TOTAL FLT CYC`S FOR PERMANENT REPAIR. QC UPDATE: PLANNING TO CONTACT ESC AFTER 60,000 TOTAL FLT CYC`S BUT BEFORE 61,000 TOTAL FLT CYC`S FOR CORRECTIVE ACTION LIMIT: INSPECT REPAIR AT 66,000 TOTAL FLT CYC`S. PLANNING TO CONTACT ESC AFTER 60,000 TOTAL FLT CYC`S NOT TO EXCEED 61,000 TOTAL FLT CYC`S FOR PERMANENT REPAIR.