What was found
CABIN FRAME CRACKED.STA>1580 BETWEEN STR 8L AND 9L. CUTOUT DAMAGE AND INSTALLED REPAIR CHANNELS REF SRM 53-00-07 REPAIR 1. INITIATED DIP 11725 FOR SUPPLEMENTAL DVI INSPECTIONS REF ZONE 2 OF TABLE 203 OF SRM 53-00-07. FRAME CRACKED BETWEEN STR 8LT AND STR 9LT PER SRM 53-00-07, REPAIR 1, PG 213, ZONE 2, COMPLETED REPAIR. INSPECT REPAIR AT 37,500 FLT CYC'S AFTER REPAIR INSTALLED, THEREAFTER EVERY 12,000 FLT CYC'S.