What was found
SUPPORT TASK - RT STAB LOWER SKIN AREA FWD OF AFT SPAR CHEM MI LL SHOWS CRACK INDICATION AT ABOUT STA 253 AREA MARKED. REPAIRED PER ECRA 5510-02204. ACCOMPLISH INITIAL INSP PRIOR TO 61613 FLT CYCLS. THEN REPEAT INSPECTIONS AT INTERVALS NOT TO EXCEED 9000 FLT CYCLES PER PART 2 OF ECRA 5510-02204. SEE ATT 00 08 FORM FOR ALL WORK PERFORMED. DIP CTL # 12474. RT HORIZ STAB LWR SKIN ANOMALY NOTED. PER ECRA 5510-02204 COMPLETED REPAIR. INSPECT REPAIR AT 61,613 TOTAL FLT CYC`S THEREAFTER EVERY 9,000 FLT CYC`S PER PART 2 OF ECRA.