What was found
SMOKED FILLED THE CABIN BETWEEN DOOR 2 AND EMERGENCY WINDOW EXIT FOR ABOUT 1 MIN WITH AN ODOR ACRID SIMILAR TO ROTTEN EGGS/ A STINK MULCH WHICH LASTED ABOUT 4 MIN AT FL380 IN CIRRUS CLOUD INSP A/C PER AMM05-51-58 PG-901-801 AND AMM05-51-31 PG BLOCK 20 1 FOUND ABOVE 2L DOOR FLUORESCENT LIGHT BULB BURNED. REMOVED/REPLACED BALLAST AND BULBS PER AMM33-21-10 962-012. OVERWING EXIT LEFT SIDE BULB BURNED OUT. RELAMP PER AMM33-51-01-962-00. A/C OK TO CONTINUE.