What was found
RIGHT STAB LOWER SKIN SHOWS CRACK INDICATION AT STA 166.30 17 INCHES FWD OF AFT SPAR REPAIRED CRACK AND INSTALLED LEADING EDGE W/REF TO SRM 55-10-01 REPAIR 11. SEE ATTACHED 44.0008 FOR PARTIAL WORK ACCOMP. PERFORM DVI AND LFEC AT 56000 FLT CYC`S AFTER REPAIR AND AT REPEAT INTERVALS OF 9000 FLT CYC`S PER TABLE 204 OF STEP 5 A RT HORIZ STAB LWR SKIN CRACKED. INSTALLED REPAIR PER SRM 55-10-01, REPAIR 11. PERFORM INSPECTION W/I 56,000 FLT CYC`S AFTER REPAIR INSTALLED, THEREAFTER EVERY 9,000 FLT CYC`S.