What was found
SUPPORT TASK - LT STAB LOWER SKIN STA 129.50 FLAW DETECTED DURING C SCAN FORWARD OF PREVIOUS REPAIR LT HORIZONTAL STAB LOWER INSPAR SKIN REPAIRED AT STA 129.50 IAW SRM 55-10-01 REPAIR 11. AFTER 56000 FLT CYC'S PERFORM INITIAL DVI AND EXTERNAL LFEC INSP. REPEAT AT INTERVALS OF 9000 FLT CYC'S PER STEP 5 A TABLE 204. PERFORM A DV INSP OF THE LT HORZ STAB LWR SKIN REPAIR LOCATED AT STA 129.50 AFTER 56,000 FLT CYC FROM DATE 2/03/2012 USING LFEC METHOD REF: B737 NDT 53-30-00 FIG 5 PART 6. REPEAT INSP AT 9,000 FLT CYC INTERVALS THERE AFTER. REF: B737-800 SRM 55-10-01 REPAIR 11. DIP C/N 14485.